The electronic stun device market is permeated with claims of extremely high voltages. Unfortunately, most of these claims have little basis in reality. As you can see in the table below from an independent published source, the advertised voltage of most stun devices is greatly exaggerated.
Model2
Advertised voltage
Actual Peak Voltage
AIR TASERTM
50,000V
50,000V
O-mega SS
120,000 V
16,400 V
Nova Spirit
20,000 V
24,900 V
STN-160
160,000 V
28,700 V
SK Thunder Power
120,000 V
25,000 V
SK Thunder 945SP
65,000 V
23,000 V
SK Sigma-7 Model C
45,000 V
20,700 V
Super Thunder
75,000 V
19,600 V
Z-Force-Ultra
150,000 V
25,200 V
Z-Force III
100,000 V
29,700 V
Z-Force I
80,000 V
20,400 V
STG-1
50-100,000 V
11,000 V
As you can see, only the Nova Spirit and AIR TASER advertise the actual voltage. The
AIR TASER has the highest, measurable, real voltage of any stun device on the market.
In reality, voltage tells you how far the spark will jump and how much clothing
the stun device can penetrate if the spark must jump through fabric. This is the only true
benefit from higher voltage (amperage and power determine how strong the pulse feels).
In order to measure the peak voltage of a stun device, simply measure the distance that
the spark jumps when you activate the stun gun into the air (measure from the
two points where the spark starts and stops). The rule of thumb is 30,000 Volts per inch.
For example, the maximum voltage of the stun gun below is 0.3 inches x 30,000 Volts/inch =
9,000 Volts.
Remember, the voltage is measured where the spark actually jumps, not from the forward
electrodes. Measure the length of the actual spark itself.
Again, there is much confusion about voltage. Voltage claims are usually not accurate.
However, calculating the length of the spark (and the voltage) will tell you how much
clothing a spark will penetrate. The best test for effectiveness is to look for the T-WaveTM
trademark and to test the unit to make sure it is built with quality and survivability.
Copies of independent tests available upon request (Fax request to 480-991-0791).
CorrectionsOne encourages its members to comment on this article in the comments section below. You must be a confirmed Corrections officer to post a comment. The comments below are member-generated and do not necessarily reflect the opinions of CorrectionsOne or its staff.